Limited Edition Golden Llama is here! Check out how you can get one. Limited Edition Golden Llama is here! Check out how you can get one.
Offering SPR-BLI Services - Proteins provided for free! Offering SPR-BLI Services - Proteins provided for free!
Thank you for choosing ACROBiosystems. Would you rate our product and service? Thank you for choosing ACROBiosystems. Would you rate our product and service?
Here come GMP Grade Cytokines!Free Sample is available! Here come GMP Grade Cytokines!Free Sample is available!
The kit is developed for quantitative detection of natural and recombinant human EPO in serum, plasma and cell culture supernatants.
It is for research use only.
Analyte | EPO |
Assay Type | Sandwich-ELISA |
Reactivity | Human |
Sensitivity | 0.67 mlU/mL |
Range | 0.87 mlU/mL-212 mlU/mL |
Assay Time | 2 hr 45 min |
Sample Type | Cell Culture Supernatants, Plasma, Serum. |
Sample volume | 50 uL |
Format | 96-wells plate breakable into 12 x 8 wells strips |
Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.
For each experiment, each ELISA plate needs to set the standard curve. The minimum detectable concentration of EPO is less than 0.67 mIU/mL.
To evaluate the intra-assay precision of assay using CEA-C027 and Competitor R, four samples spiked with different concentrations of EPO were tested. Results shown in the following Table. CV values of all analytes are less than 6%. Acceptable criteria : CV<10%.
To evaluate the hemolysis matrix effect and high-dose triglyceride matrix effect of assay, serum samples spiked with high concentrations of hemoglobin (2%), or triglyceride (3 mg/mL) were tested. Results shown that all spiked analytes had recoveries between 90% and 110%, no hemolysis matrix effect and high-dose triglyceride matrix effect was observed in assay using CEA-C027.
To evaluate the hook effect of the assay, some samples with high concentration of EPO were tested. Results shown in the following figure. No hook effect was found in the assay using the CEA-C027.
To evaluate the linearity of assay using CEA-C027 and Competitor R, samples (Serum, EDTA plasma) spiked with high concentrations of EPO were serially diluted with dilution buffer to produce samples with values within the dynamic range of the assay. Results shown that recoveries of all analytes are less than 120%. Acceptable criteria: Recovery should be between 80% and 120%.
To evaluate the recovery of assay using CEA-C027 and Competitor R, samples (Serum, EDTA plasma) spiked with low concentrations of EPO (LQC) were tested. All analytes had recoveries between 80% and 100%. Acceptable criteria: Recovery should be between 80% and 120%.
To evaluate the consistency of assay using CEA-C027 and Competitor R, 40 healthy serum samples and 14 patient serum samples were tested, and these results demonstrated a high degree of consistency between the two products, R² >0.95.
ID | Components | Size |
CEA027-C01 | Pre-coated Anti-EPO Antibody Microplate | 1 plate |
CEA027-C02 | Human EPO Standard | 3392 IU×2 |
CEA027-C03 | Biotin-Anti-EPO Antibody Con. Solution | 100 μL |
CEA027-C04 | Biotin-Antibody Dilution Buffer | 8 mL |
CEA027-C05 | Streptavidin-HRP Con. Solution | 500 μL |
CEA027-C06 | HRP Dilution Buffer | 15 mL |
CEA027-C07 | 20× Washing Buffer | 50 mL |
CEA027-C08 | Sample Dilution Buffer | 15 mL×2 |
CEA027-C09 | Substrate Solution | 12 mL |
CEA027-C10 | Stop Solution | 6 mL |
ACROBiosystemsは、二重特異性抗体の治療薬への臨床開発を加速するために、高い生物活性を持つ均一なCD3δ/CD3εおよびCD3γ/CD3εタンパク質のシリーズを開発しました。
We offer a wide range of cell and gene therapy solutions starting from discovery to the clinic. Explore our wide range of proteins, antibodies, kits, and other assays to accelerate the development of your cell and gene therapy.
Organoid Toolbox は、即使用可能のオルガノイド、オルガノイド分化ツールキット、創薬プロジェクトの進行を加速する、さまざまなサービスを含むオルガノイドソリューションのことです。
IL-15、IL-7、IL-21など、高品質のGMP準拠サイトカイン製品を提供しており、免疫細胞治療薬の臨床研究をサポートし、医薬品規制当局の承認を加速できます。
注目されている50以上のCAR-Tターゲットがあり、CARの発現の検出のために設計された抗原タンパク質をフローサイトメトリーで検証し、CARの発現が高い特異性で検出できます。ロット間の一貫性が保証されています。また、PE / FITC標識タンパク質を利用することで、ワンステップ染色でCARの発現を高い特異性でバックグラウンドなしに検出できます。
CD20、Claudin18.2、CD133、GPRC5D、CCR5、CCR8などの安定で高活性な全長型膜貫通タンパク質は、免疫学、ELISA、SPR、BLI、細胞実験、CAR陽性率検出に利用できます。VLP、界面活性剤、ナノディスクなどのテクニカルプラットフォームによって複数回膜貫通タンパク質の医薬品創薬を促進できます。
GMP準拠サイトカイン、高品質の細胞活性化/増幅試薬、遺伝子改変試薬/酵素、CAR検出試薬などの製品を提供し、細胞、遺伝子治療用に全体的なソリューションを提供し、創薬から臨床研究までのすべての段階をサポートします。
これまでに知られている免疫チェックポイント分子をほぼ製品化しており、様々なタグの製品群を提供できます。天然高分子の構造はMALSによって、生物活性はELISA/SPR/BLI/FACSなどによって検証済みです。またBiotin/FITCなどの標識も選択でき、抗体のハイスループットスクリーニングに利用できます。
弊社ACROBiosystemsはADC医薬品の開発のサポートに取り組み、注目されている様々なターゲットのために、異なる種類とタグの製品が開発され、高い純度と親和性が特長です。免疫、抗体スクリーン、SPR、細胞活性検査などの実験に利用できます。Protocolも無償で提供いたします。
すべての分子のFc受容体タンパク質だけでなく、一般的な変異体やビオチン標識タイプも含まれております。お客様のモノクローナル抗体の開発をサポートします。
インターロイキン、成長因子、ケモカイン、TNF など、様々なサイトカインターゲットの自然なコンフォメーションを確保するために HEK293 によって発現されます。SDS-PAGE/HPLC/SEC-MALS によって高純度は確認され、高い生物活性は ELISA/SPR/BLI によって確認されています。
AneuroはACROBiosystemsが神経科学研究のために設計した製品群のブランドです。神経科学研究を推進するための治療・診断用研究タンパク質、PFF、組み換え神経因子など、高品質の重要なタンパク質を提供しております。
This web search service is supported by Google Inc.