Anti-Mouse IgG-Acridinium ester

ユーザーレビュー
製品番号/仕様
価格
Availability
数量
AMG-S163-100ug
$70.00
In Stock - Delivery in 2-3 business days
AMG-S163-1mg (250ug X 4)
$705.00
総アイテム数 製品金額$ 0

製品詳細

  • Source

    Anti-Mouse IgG-Acridinium ester is a chimeric monoclonal antibody recombinantly expressed in human 293 cells(HEK293), which combines the variable regions of a mouse monoclonal antibody with rabbit IgG constant domains.

  • Antibody Type

    Recombinant Monoclonal

  • Clone

    AS163

  • Isotype

    Rabbit IgG, Kappa

  • Host Species

    Mouse

  • Conjugate

    Acridinium ester conjugated

  • Specificity

    This product is a specific antibody specifically reacts with Mouse IgG.

  • Purification

    Protein A purified.

  • Aggregation

    Less than 10%, as determined by SEC-MALS.

  • Concentration

    Please refer to the Certificate of Analysis (CoA).

  • Form

    Lyophilized

  • Formulation

    Lyophilized from a 0.22 μm-filtered solution in PBS, pH6.3, with trehalose as protectant.

    Please contact us for customized product forms or formulations.

  • Reconstitution

    Please refer to the Certificate of Analysis (CoA) for specific instructions.

  • Shipping

    Lyophilized product is shipped at ambient temperature.

  • Storage

    For long term storage, the product should be stored in a lyophilized state at -20°C or lower.

    Please protect from light and avoid repeated freeze-thaw cycles.

    This product is stable after storage at:

    1. -20°C to -70°C for 12 months in lyophilized state;
    2. -70°C for 3 months under sterile conditions after reconstitution.
  • Notices

    Product Specific Notices: For research use only.

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

お客様はこちらも閲覧

データ表示

  • Bioactivity-MPCLIA

     Mouse IgG MPCLIA

    Immobilized 0.04 μg /Test of Biotinylated Human PD-1, Avitag,His Tag (recommended for biopanning) (Cat. No. PD1-H82E4) to the Streptavidin-Magnetic Beads (used for MPCLIA) (Cat. No. MPC-A006, 20 μg beads/Test), incubated with 100 μL /Test of Human PD-L1, Mouse IgG1 Fc Tag, low endotoxin (Cat. No. PD1-H52A3) at increasing concentration coupled to Anti-Mouse IgG-Acridinium ester (Cat. No. AMG-S163, 0.04 μg /Test). Detection was performed with sensitivity of 1.5625 ng/mL in Magnetism particulate chemiluminescence immunoassay (MPCLIA) (KEYSMILE, SMART 6500S) (QC tested).

    Protocol
  •  Mouse IgG MPCLIA

    The MPCLIA assay shows that Anti-Mouse IgG-Acridinium ester (Cat. No. AMG-S163) is stable at 37°C for 48 hours.

    Protocol
  •  Mouse IgG MPCLIA

    The MPCLIA assay shows that Anti-Mouse IgG-Acridinium ester (Cat. No. AMG-S163) is stable after freezing and thawing 3 times.

    Protocol

ユーザーレビュー
コメントを投稿

よくある質問

  • product

    Can lyophilized proteins remain stable during room-temperature shipping or temporary room-temperature exposure?

    In general, lyophilized proteins remain stable during room-temperature shipping or temporary exposure to room-temperature conditions.


    Many ACROBiosystems recombinant proteins are supplied in lyophilized (freeze-dried) form. The lyophilization process effectively removes moisture from the product, helping reduce degradation-related reactions and improve protein stability during transportation and storage.


    To evaluate the stability of lyophilized proteins under normal temperature conditions, ACROBiosystems conducted a stability study on 11 representative lyophilized protein products at 37°C. The study demonstrated that these proteins maintained good quality stability after storage at 37°C for approximately 20 days. Based on these validation results, temporary room-temperature exposure during shipping or handling is generally not expected to have a significant impact on product quality or downstream application performance.


    To ensure optimal long-term stability, products should be stored according to the storage conditions specified in the product Certificate of Analysis (COA) upon receipt.


    Supporting Document


バックグランド

Chemiluminescence immunoassay (CLIA) is a much more effective measurement with the advantages of high sensitivity, uniformity and broad dynamic range.
However, in traditional chemiluminescent immunoassay (CLIA),microplate was applied to immobilize antigen or antibody by physical absorption, which holds a negative effect on the perfor-mance of assay because of the low specific surface area of micro-plate.
The use of micromagnetic particles (MMPs) have proven to be a support for addressing the shortage of traditional CLIA mentioned above The chemiluminescent immunoassay is a technique used for disease diagnosis, drug development, chemical reaction monitoring, and many other applications.
The MMPs-based chemiluminescence immunoassays could improve the surface area for immobilization, capture efficiency and accuracy of the assay, thus obtaining higher sensitivity and shorter analysis time.

最新の進展

 
お問い合わせ
医薬品候補ライセンス
他の関連情報
  • 製品情報
  • 製品詳細
  • お客様はこちらも閲覧
  • データ表示
  • ユーザーレビュー
  • よくある質問
  • 背景
お問い合わせ

お問い合わせ
グローバル:+1 800-810-0816(Toll Free)

メールアドレス
order.jp@acrobiosystems.com

アクロバイオシステムズ株式会社
〒101-0051
東京都千代田区神田神保町1-32-8