AAV8 Titration ELISA Kit

ユーザーレビュー
製品番号/仕様
価格
数量
AAV-A008-96tests
$565.00
ETA of in-stock products:2 business days
総アイテム数 製品金額$ 0

製品詳細

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    AAV8
    Format
    96T
    Regulatory Status
    RUO
    Sensitivity
    <1.75E+07 capsids/mL
    Standard Curve Range
    5.60E+08 capsids/mL-1.75E+07 capsids/mL
    Assay Time
    3 hr 20 min
    Suitable Sample Type
    For the detection and quantitative determination of AAV8 capsid titration in AAV gene therapy product preparation processing.
    Sample volume
    100 μL

  • Product Overview

    AAV8 Titration ELISA Kit is based on the sandwich-ELISA method and is used to detect and quantitatively determine the AAV8 capsid titration in AAV gene therapy product winthin 3 hr 20 min. The kit is designed to provide reliable solutions for the early development, production, and quality control of AAV gene therapy products.

  • Reconstitution

    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.

  • Storage

    1. Unopened kit should be stored at 2℃-8℃ upon receiving.

    2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    AAV08-C01
    Pre-coated Anti-AAV8 Antibody Microplate
    1 plate
    AAV08-C02
    AAV8 Standard
    1.4E+10 capsids
    AAV08-C03
    Biotin-Anti-AAV8 Antibody
    15 μg
    AAV08-C04
    Streptavidin-HRP
    50 μL
    AAV08-C05
    10×Washing Buffer
    50 mL
    AAV08-C06
    2×Dilution Buffer
    50 mL
    AAV08-C07
    Substrate Solution
    12 mL
    AAV08-C08
    Stop Solution
    7 mL

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

お客様はこちらも閲覧

データ表示

  • Typical Data 

    Please refer to DS document for the assay protocol.

     AAV8 TYPICAL DATA

    For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.