SAFENSURE™ Recombinant Factor C Endotoxin Detection Kit

Cat. No. / Size
Price
Availability
Qty
RES-A056-48tests
$220.00
In Stock - Delivery in 2-3 weeks
RES-A056-96tests
$350.00
In Stock - Delivery in 1-2 business days
Endotoxin-Free Glass Test Tubes
RES-A127-2boxes (1box X 2)
$200.00
In Stock - Delivery in 1-2 business days
LER Sample Dilution Buffer
RES-A129-1box
$50.00
In Stock - Delivery in 1-2 business days
RES-A056
Sub-Total :
$ 0
Customize Product Request Quote
Contact Us
Contact Us
Sub-Total:
$ 0
  • Product Details
  • Performance Data
  • Reviews & Citations
  • Important Statement
  • Resources
FAB
  • Comparable to LAL method - Endpoint fluorescent assay, comparable to other chromogenic quantitative LAL methods.
  • High specificity - Unlike LAL Assay, as Factor G is absent from the rFC test kit, false-positive results due to β-glucan activation are not expected to occur.
  • Accuracy - Traceability of endotoxin standards in the kit against USP Standard (Catalog No: 1235503).
  • Fast time to results - 1 hour.
  • High sensitivity - Sensitivity range from 0.005-5 EU/mL.
  • Rapid Assay - Sensitivity range from 0.01-10 EU/mL.
  • Extensive validation - Verification on multiplex biological products, kinds of microplate readers and various buffer systems, comprehensive validation of specificity, sensitivity, precision, accuracy, applicability, and other aspects according to the parameters listed in the EUROPEAN PHARMACOPOEIA 11.0, USP Chapter<1225> and <86>
  • Sustainable resource - Get rid of dependence on animal derived reagents, reduce dependence on horseshoe crab resources and fishing pressure and realize long-term supply.
  • Good inter batch consistency - Batch consistency of products is guaranteed due to the use of genetic recombination technology for production.
Recombinant C Protein: Saving Horseshoe Crabs for a Greener Future
Endotoxin PRODUCT Impression
Product Overview

The Recombinant Factor C Endotoxin Detection Kit is a novel endotoxin detection method based on the recombination technology. Recombinant Factor C, as the first component of the horseshoe crab coagulation cascade reaction, is activated by an endotoxin. The activated Factor C can cleave the fluorogenic substrate and produce a fluorescent signal. The increase of fluorescence signal is positively correlated with the dosage of endotoxin. The experiment is carried on a white 96-well plate and is measured at time zero and after a one-hour 37℃ incubation. Use a fluorescence microplate reader to measure at the wavelength of ex/em = 380/440 nm to determine whether the sample is contaminated by endotoxin.

Assay Principles

The Recombinant Factor C Endotoxin Detection Kit is a novel endotoxin detection method based on the recombination technology. Recombinant Factor C, as the first component of the horseshoe crab coagulation cascade reaction, is activated by an endotoxin. The activated Factor C can cleave the fluorogenic substrate and produce a fluorescent signal. The increase of fluorescence signal is positively correlated with the dosage of endotoxin. The experiment is carried on a white 96-well plate and is measured at time zero and after a one-hour 37℃ incubation. Use a fluorescence microplate reader to measure at the wavelength of ex/em = 380/440 nm to determine whether the sample is contaminated by endotoxin.

Assay Principles

Materials Provided

ID
Components
Size
RES056-C01
Bacterial Endotoxin Standard
1 vial
RES056-C02
Recombinant Factor C Protein
48 tests/96 tests
RES056-C03
Fluorogenic Substrate
48 tests/96 tests
RES056-C04
Water for Bacterial Endotoxins Test
50 mL
RES056-C05
96 Well Endotoxin Free Black Plate
1 plate

Application
Production process (Process control)
  • Raw materials
  • Water testing
  • Intermediate product testing
Final product (Release testing)
  • Parenteral drugs & Biological products
  • Infusion, injection or tranfusion cells
  • Cell culture media
  • Medical devices

It is for research use only.

Storage

1. Store the unopened kit at 2-8°C upon receipt.

2. Locate the expiration date on the outer packaging and do not use reagents beyond their expiration date.