Inhibitor Screening Kits

Inhibitor screening plays a crucial role in drug development, particularly in the early stages. The process involves screening a large number of candidate molecules to identify those with notable pharmacological effects, which are then further evaluated. To efficiently screen multiple potential inhibitors, rapid and sensitive tools are required.

To efficiently screen multiple potential inhibitors by developing an inhibitor screening platform based on the competitive ELISA method. We offer a series of high-sensitivity inhibitor screening kits that utilize unique in-house biotinylated proteins. These kits are designed for preliminary screening and quality control in drug development, providing researchers with reliable, efficient, and accurate tools for inhibitor screening.

Product Features

Accurate & Reliable: Verified raw materials with high batch-to-batch consistency ensure stable and reliable experimental results.

Easy-to-use & Time-saving: Simple, 4-step ELISA procedure has been pre-validated to eliminate time-consuming method development and validations.

Minimal Matrix Effects: Interfering substances, including DMSO, were studied to ensure kit compatibility with small and macro-molecule inhibitors.

High Repeatability: Kits are highly stable and have minimal lot-to-lot variation and use our site-specific biotin labeling platform.

Overview

Quantity 96 tests
Detection Method Colorimetric
Method Type Competitive ELISA
Applications High-throughput screening antibodies, small molecule inhibitors, peptide, etc.

Schematic Diagram

Notes: The assay employs a simple colorimetric ELISA platform which is based on the competitive binding technique. (The principles between different inhibitor screening kits are slightly different)

The experimental protocol includes 4 short steps:

  • Coat the plate with human PD-L1.

  • Add Human PD-1-Biotin to bind the coated human PD-L1.

  • Add your molecule of interest  to the tests.

  • Add Streptavidin-HRP followed by TMB or other colorimetric HRP substrate.

Finally, the ability of your compound to inhibit PD-1: PD-L1 binding will be determined by comparing OD readings among different experimental groups.

Components

Take PD-1 [Biotinylated] : PD-L1 Inhibitor Screening ELISA Kit (EP-101) for example.

ID Components Size
EP101-C01 High-bind Plate 1 plate
EP101-C02 Human PD-L1 25 μg
EP101-C03 Anti-PD-1    Neutralizing Antibody 20 μg
EP101-C04 Human PD-1-Biotin 5 μg
EP101-C05 Streptavidin-HRP 10 μg
EP101-C06 Coating Buffer 12 mL
EP101-C07 10xWashing Buffer 50 mL
EP101-C08 Blocking Buffer 50 mL
EP101-C09 Substrate Solution 12 mL
EP101-C10 Stop Solution 7 mL

Product List

Cat. No.MoleculeProduct Description予約/注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
事前注文
注文
注文
注文
注文
注文
注文
事前注文
事前注文
事前注文
注文
事前注文
事前注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文
注文

Supplement Data

Inhibition of PD-1: PD-L1 binding by anti-PD-1 neutralizing antibody measured using the PD-1 [biotinylated]: PD-L1 inhibitor screening ELISA assay pair (Cat. No. EP-101).

Anti-PD-1 neutralizing antibody was diluted from 10 μg/mL to 0.078 μg/ mL (69.628 nM to 0.544 nM) and loaded onto the plate coated by human PD-L1 in the presence of human PD-1-Biotin. Assay was performed according to the protocol in PD-1[Biotinylated] : PD-L1 Inhibitor Screening ELISA Assay Pair. Background was subtracted from data points prior to log transformation and curve fitting (QC tested).

Inhibition of TL1A [Biotinylated] : DR3 binding by anti-TL1A neutralizing antibody measured using TL1A [Biotinylated] : DR3 inhibitor screening kit (Cat. No. EP-168)

Serial dilutions of Human Anti-TL1A Neutralizing antibody (Catalog # EP168-C04) (1:1 serial dilution, from 5 μg/mL to0.0390625 μg/mL) was added into Human DR3: Biotinylated Human TL1A binding reactions. The assay was performed according to the protocol described below. Background was subtracted from data points prior to log transformation and curve fitting (QC tested). For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The example data is for reference only.

Inhibition of IL-4: IL-4 R alpha binding by Human IL-4 measured using IL-4 [biotinylated]: IL-4 R alpha inhibitor screening kit (Cat. No. EP-132).

Serial dilutions of Human IL-4(Catalog # EP132-C03) (1:1 serial dilution, from 5 μg/mL to 0.01 μg/mL (295.86-0.58 nM)) was added into IL-4 R alpha: IL-4-Biotin binding reactions. The assay was performed according to the above-described protocol. Background was subtracted from data points prior to log transformation and curve fitting (QC tested).

Inhibition of Integrin α 4 β 7: MAdCAM-1binding by anti-Integrin α 4 β 7 neutralizing antibody measured using Integrin α 4 β 7: MAdCAM-1 [Biotinylated] inhibitor screening kit (Cat. No. EP-155)

Serial dilutions of Anti-Integrin α 4 β 7 Neutralizing antibody (Catalog # EP155-C04) (1:1 serial dilution, from 5 μg/mL to 0.0098μg/mL) was added into Integrin α 4 β 7: Biotinylated MAdCAM-1 binding reactions. The assay was performed according to the protocol described below. Background was subtracted from data points prior to log transformation and curve fitting (QC tested).

Related product

Immune-Checkpoint

Interleukin

enzyme

  • Background
  • Product Features
  • Overview
  • Schematic Diagram
  • Components
  • Product List
  • Supplement Data
  • Related product
お問い合わせ

お問い合わせ
グローバル:+1 800-810-0816(Toll Free)

メールアドレス
order.jp@acrobiosystems.com

アクロバイオシステムズ株式会社
〒101-0051
東京都千代田区神田神保町1-32-8