Product Details
Assay TypeSandwich-ELISA
AnalyteCCL17
Format96T
ReactivityHuman
Sensitivity3.0pg/mL
Standard Curve Range31.25pg/mL-2000 pg/mL
Assay Time2hr
Suitable Sample TypeFor the quantitative determination of human CCL17 in Cell Culture Supernatants, Plasma, Serum.
Sample volume50ul
Materials Provided
IDComponentsSize
CEA029-C01Pre-coated Anti-CCL17 Antibody Microplate1 plate
CEA029-C02Human CCL17 Standard500 μL
CEA029-C03Biotin-Anti-CCL17 Antibody Con. Solution100 μL
CEA029-C04Biotin-Antibody Dilution Buffer8 mL
CEA029-C05Streptavidin-HRP Con. Solution0.5 mL
CEA029-C06Streptavidin-HRP Dilution Buffer15 mL
CEA029-C0720× Washing Buffer50 mL
CEA029-C08Sample Dilution Buffer15 mL ×2
CEA029-C09Substrate Solution12 mL
CEA029-C10Stop Solution6 mL
  • Background
    ClinMax™ ELISA Kit is convenient ready-to-use immunoassay Kit, specifically designed to quantitate human TARC/CCL17 that is present in complex biological samples, such as human serum, plasma, and cell culture supernates.

    A comprehensive validation of the ELISA method was performed following the ICH M10 on bioanalytical method validation and the FDA’s bioanalytical method validation guidance for industry. This validation included assessments of linearity, accuracy, precision, dilution linearity, recovery, and the hook effect. For details information, please refer to the DS.

    ClinMax™ ELISA Kits are manufactured in a GMP-certified facility and comply to the ISO 13485 standard, ensuring a high level of quality and reliability.

  • Application

    The kit is developed for quantitative detection of human TARC/CCL17 in serum, plasma and cell culture supernates.

    It is for research use only.

  • Storage
    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
  • Assay Principles
     TARC/CCL17 Assay Principles
Typical Data Please refer to DS document for the assay protocol.
 TARC/CCL17 TYPICAL DATA

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of CCL17 is less than 3 pg/mL.