Product Overview
Human Amyloid beta 1-40 ELISA Kit is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant humanAmyloid beta 1-40 that is present in biological samples. Our ELISA Kit provides several benefits:
- Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
- High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
- Simplified and straightforward protocols and ready-to-use reagents to save assay time.
Product Specifications
Assay TypeSandwich-ELISAAnalyteAmyloid beta 1-40Format96-wells plate breakable into 12 x 8 wells stripsReactivityHumanSensitivity400 pg/mLAssay Time2.25 hrSample volume20 μLRange447 pg/mL-7500 pg/mLSample TypeFor the quantitative determination of human Amyloid beta 1-40 in Cerebrospinal Fluid.Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.
Application
The kit is developed for quantitative detection of natural and recombinant human Amyloid beta 1-40 in cerebrospinal fluid.
It is for research use only.
Workflow

Storage
Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
Materials Provided
IDComponentsSizeCEA248-C01Pre-coated Anti-Amyloid beta 1-40 Antibody Microplate1 plateCEA248-C02Human Amyloid beta 1-40 Standard3 μg×2CEA248-C03Biotin-Anti-Amyloid beta 1-40 Antibody Con. Solution100 μLCEA248-C04Biotin-Antibody Dilution Buffer8 mLCEA248-C05Streptavidin-HRP Con. Solution500 μLCEA248-C06Streptavidin-HRP Dilution Buffer15 mLCEA248-C0720×Washing Buffer50 mLCEA248-C08Sample Dilution Buffer15 mL×2CEA248-C09Substrate Solution12 mLCEA248-C10Stop Solution6 mLACRO Quality Management System
お客様はこちらも閲覧
データ表示
Typical Data
Please refer to DS document for the assay protocol.

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of Amyloid beta 1-40 is less than 400 pg/mL.
Sample Values
Ten healthy Cerebrospinal Fluid samples were evaluated for the concentrations of human Amyloid beta 1-40 in assay.

Intra-Assay Statistics
Ten replicates of each of three samples containing different Amyloid beta 1-40 concentrations were tested in one assay. Acceptable criteria: CV<10%.

Inter-Assay Statistics
Three samples containing different concentrations of Amyloid beta 1-40 were tested in independent assays. Acceptable criteria: CV<15%.

Recovery
Recombinant Amyloid beta 1-40 was spiked into three human Cerebrospinal Fluid samples, and then analyzed. The average recovery of Amyloid beta 1-40 for Cerebrospinal Fluid samples is 93.7%.