製品詳細
Product Overview
rHuman Sonic Hedgehog/Shh ELISA Kit is a ready-to-use immunoassay kit, specifically designed to quantitate recombinant human Sonic Hedgehog/Shh that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ELISA Kit provides several benefits:
- Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
- High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
- Simplified and straightforward protocols and ready-to-use reagents to save assay time.
Product Specifications
Assay TypeSandwich-ELISAAnalyteSonic Hedgehog/ShhFormat96-wells plate breakable into 12 x 8 wells stripsReactivityHumanSensitivity30 pg/mLAssay Time2.75 hrSample volume50 μLRange46.875 pg/mL-3000 pg/mLSample TypeFor the quantitative determination of rHuman Sonic Hedgehog in BSS.Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.
Application
The kit is developed for quantitative detection of recombinant human Sonic Hedgehog/Shh in serum, plasma and cell culture supernatants.
It is for research use only.
Workflow

Storage
Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
Materials Provided
IDComponentsSizeCEA239-C01Pre-coated Anti-Shh Antibody Microplate1 plateCEA239-C02rHuman Shh Standard30 ng×2CEA239-C03Biotin-Anti-Shh Antibody Con. Solution100 μLCEA239-C04Biotin-Antibody Dilution Buffer8 mLCEA239-C05Streptavidin-HRP Con. Solution500 μLCEA239-C06Streptavidin-HRP Dilution Buffer15 mLCEA239-C0720× Washing Buffer50 mLCEA239-C08Sample Dilution Buffer15 mL×2CEA239-C09Substrate Solution12 mLCEA239-C10Stop Solution6 mLACRO Quality Management System
お客様はこちらも閲覧
データ表示
Typical Data
Please refer to DS document for the assay protocol.

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of recombinant Sonic Hedgehog/Shh is less than 30 pg/mL.
Intra-Assay Statistics
Ten replicates of each of three samples containing different Sonic Hedgehog/Shh concentrations were tested in one assay. Acceptable criteria: CV<10%.

Inter-Assay Statistics
Three samples containing different concentrations of Sonic Hedgehog/Shh were tested in independent assays. Acceptable criteria: CV<15%.

ユーザーレビュー コメントを投稿

最新の進展
メールアドレス
order.jp@acrobiosystems.comお問い合わせ
グローバル:+1 800-810-0816(Toll Free)