Human TARC/CCL17 ELISA Kit

ユーザーレビュー
製品番号/仕様
価格
数量
CEA-C029-96tests
$565.00
CEA-C029-480tests (96tests X 5)
$2545.00
ETA of in-stock products:2 business days
総アイテム数 製品金額$ 0

製品詳細

  • Product Overview

    Human TARC/CCL17 ELISA Kit is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human TARC/CCL17 that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ELISA Kit provides several benefits:

    1. Standards to calibrate with NIBSC/WHO standards for comparable results.
    2. Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
    3. High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
    4. Simplified and straightforward protocols and ready-to-use reagents to save assay time.

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    CCL17
    Format
    96-wells plate breakable into 12 x 8 wells strips
    Reactivity
    Human
    Sensitivity
    3.0 pg/mL
    Assay Time
    1.75 hr
    Sample volume
    50 μL
    Range
    31.25pg/mL-2000 pg/mL
    Sample Type
    Cell Culture Supernatants, Plasma, Serum.

    Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.

  • Application

    The kit is developed for quantitative detection of natural and recombinant human TARC/CCL17 in serum, plasma and cell culture supernatants. It is for research use only.

    It is for research use only.

  • Workflow

    TARC/CCL17 Workflow

  • Storage

    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    CEA029-C01
    Pre-coated Anti-CCL17 Antibody Microplate
    1 plate
    CEA029-C02
    Human CCL17 Standard
    500 μL
    CEA029-C03
    Biotin-Anti-CCL17 Antibody Con. Solution
    100 μL
    CEA029-C04
    Biotin-Antibody Dilution Buffer
    8 mL
    CEA029-C05
    Streptavidin-HRP Con. Solution
    0.5 mL
    CEA029-C06
    Streptavidin-HRP Dilution Buffer
    15 mL
    CEA029-C07
    20×Washing Buffer
    50 mL
    CEA029-C08
    Sample Dilution Buffer
    15 mL×2
    CEA029-C09
    Substrate Solution
    12 mL
    CEA029-C10
    Stop Solution
    6 mL
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

お客様はこちらも閲覧

データ表示

  • Typical Data 

    Please refer to DS document for the assay protocol.

     TARC/CCL17 TYPICAL DATA

    For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of CCL17 is less than 3 pg/mL.

Validation
  • Sample Values

    Serum Sample: TARC/CCL17 concentrations were measured in thirty-two human serum samples, which were collected from healthy human subjects. The measurements of thirty-two samples are in the range of 1000-4000pg/mL and shown in the figure below.

     TARC/CCL17 SAMPLE VALUES

    Cell Culture Supernatant: Human peripheral blood mononuclear cells (PBMCs) were cultured and stimulated using 10 μg/mL PHA, then detected CCL17 secretion amount on Day1, Day 3 and Day 5.

     TARC/CCL17 SAMPLE VALUES
  • Matrix Effect

    Three types of materials were tested to observe if there were matrix effect (interference). If the concentration of hemoglobin (simulated hemolysis) is less than 3500 mg/dL(2%), the concentration of triglyceride (simulated lipid blood) is less than 3 mg/mL, testing results will not be affected.

     TARC/CCL17 MATRIX EFFECT
  • Dilution Linearity

    High concentrations of human TARC/CCL17 serum samples were diluted with 1:2, 1:4, 1:8 and 1:16 ratios for gradient dilution to evaluate the linearity of the assay. In the serum samples, the average detection rate of TARC/CCL17 was 97.89%.

     TARC/CCL17 DILUTION LINEARITY
  • Intra-Assay Statistics

    Ten replicates of each of three samples containing different TARC/CCL17 concentrations were tested in one assay. Acceptable criteria: CV<10%.

     TARC/CCL17 INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Three lots of samples containing different concentrations of TARC/CCL17 were tested in the independent assays. Acceptable criteria: CV<15%.

     TARC/CCL17 INTER-ASSAY STATISTICS
  • Recovery

    TARC/CCL17 was spiked into three human serum samples, and then analyzed. The average recovery of TARC/CCL17 for serum samples is 93.93%.

     TARC/CCL17 RECOVERY

ユーザーレビュー
コメントを投稿

最新の進展

 
お問い合わせ
医薬品候補ライセンス
他の関連情報
  • 製品情報
  • 製品詳細
  • お客様はこちらも閲覧
  • データ表示
  • ユーザーレビュー
お問い合わせ

お問い合わせ
グローバル:+1 800-810-0816(Toll Free)

メールアドレス
order.jp@acrobiosystems.com

アクロバイオシステムズ株式会社
〒101-0051
東京都千代田区神田神保町1-32-8